You must agree with the terms below to view. [I Agree]

General Terms of Use

By accessing and browsing Healing Light Seminars’ Laser Research Library you accept, without limitation or qualification, the Terms of Use outlined below and acknowledge full and complete acceptance of these terms. Please review the following terms carefully. If you do not agree to these terms, you should not use the Laser Research Library.

Terms and Conditions

1.Copying or redistribution of any portion of the Laser Research Library in any manner for personal gain or commercial use, including commercial publication, or as a component of any internet, intranet or extranet database, information storage and retrieval system, or other compilation in any media now or in the future by any means is strictly prohibited.

2.Users may download these files for their personal use subject to the limitations of fair use as defined in the United States copyright laws and any additional terms or restrictions which may apply. You are granted a non-exclusive, non-transferable, revocable license to access and use material strictly in accordance with this Agreement, solely for internal, personal, non-commercial purposes; and to print out discrete information solely for internal, personal, non-commercial purposes provided that you maintain all copyright and other policies contained therein.

3.Any party wishing to use any of these files for any purpose other than the limited purposes identified above, must request and receive prior written approval from Healing Light Seminars and/or the copyright owner. Permission shall be granted on a case-by-case basis at the sole discretion of Healing Light Seminars and/or the copyright owner.

4.This material is offered for educational purposes only. It is neither complete nor comprehensive for the conditions addressed, nor should it be relied on solely to propose a course of treatment for a particular individual nor used as a substitute for a consultation or advice from a qualified, medical or health professional. Healing Light Seminars, Inc. expressly disclaims any and all liability for any kind of loss or risk, personal or otherwise, which may be sustained as a result of the direct or indirect use of this material and makes no representations or warranties as to its accuracy or completeness.

5.You agree to indemnify, defend and hold harmless Healing Light Seminars, its officers, employees and agents, from and against any and all claims, causes of action, allegations, costs, expenses, fees (including but not limited to reasonable attorney's fees), judgments, liabilities, losses and damages arising from or relating to your use of this information and website.

6.Healing Light Seminars may at any time revise these Terms and Conditions by updating this posting. You are bound by any such revisions and should therefore periodically visit this page to review the then-current Terms and Conditions.

Digital Millenium Copyright Act (DMCA) Notices; Copyright Agent

Healing Light Seminars respects the intellectual property rights of others. If you believe that your work has been copied in a way that constitutes copyright infringement by any content or material in this Laser Research Library, please provide the following information in writing to Healing Light Seminars Copyright Agent (see 17 U.S.C. Section 512(c)(3) for further details):

  1. A physical or electronic signature of a person authorized to act on behalf of the owner of the copyright.
  2. A description of the copyrighted work that you claim has been infringed.
  3. A description of the material that you claim to be infringing or to be the subject of infringing activity and that is to be removed or access to which is to be disabled, and information sufficient to permit us to locate the material.
  4. Information so that we can contact you, such as address, telephone number and e-mail address.
  5. A statement that you have a good faith belief that use of the material in the manner complained of is not authorized by the copyright owner, its agent, or the law.
  6. A statement that the information in the notification is accurate and, under penalty of perjury, that you are the copyright owner or are authorized to act on behalf of the owner of a copyright that is allegedly infringed.

Linking to the Laser Research Library

You may be granted permission to provide links to the Laser Research Library at the discretion of Healing Light Seminars and upon its terms by requesting written permission by e-mail or letter in advance from us, provided (a) that you do not remove or obscure, by framing or otherwise, the copyright notice or any other content as displayed by us in the opening page and in the body of the Laser Research Library, (b) your site does not engage in illegal, unethical or pornographic activities, and (c) you discontinue providing links to Healing Light Seminars Laser Research Library immediately upon request by us.

I Agree with these terms.

I Agree with these terms.

Provided by www.HealingLightSeminars.com
Equipment, Education and Resources for Clinical Excellence in Energetic Therapies

Coronary Stent Implantation

J Clin Laser Med Surg. 2001 Oct;19(5):261-5.

Optimal dosing of intravascular low-power red laser light as an adjunct to coronary stent implantation: insights from a porcine coronary stent model.

De Scheerder IK, Wang K, Zhou XR, Szilard M, Verbeken E, Ping QB, Yanming H, Jianhua H, Nikolaychik V, Moses JW, Kipshidze N, Van de Werf F.
University Hospitals, Leuven, Belgium.

BACKGROUND: It is believed that restenosis following coronary interventions is the result of endothelial denudation that leads to thrombus formation, vascular remodeling, and smooth muscle cell proliferation. Low-power red laser light (LPRLL) irradiation enhances endothelial cell growth in vitro and in vivo, and reduces restenosis in animal models. The present study investigated the optimal dose of intravascular LPRLL therapy in the prevention of in-stent stenosis in a porcine coronary stent model. METHODS AND RESULTS: Selected right coronary artery segments were pretreated with a LPRLL balloon, delivering a dose of 0 mW during 1 min (group 1, n = 10), 50 mW during 1 min (group II, n = 10), or 100 mW during 1 min (group III, n = 10) before stenting. Quantitative coronary analysis of the stented vessel was performed before stenting, immediately after stenting, and at 6 weeks follow-up. The pigs were sacrificed, and histologic and morphometric analyses were conducted. At 6 weeks, minimal luminal stent diameter was significantly narrower in the control group compared to the 50-mW dose group (p < 0.05). These results were confirmed by morphometric analysis. Neointimal area was also significantly decreased in the 50-mW dose group. CONCLUSIONS: Intravascular LPRLL contributes to reduction of angiographic in-stent restenosis and neointimal hyperplasia in this animal model. The optimal dose using the LPRLL balloon system seems to be approximately 5 mW delivered during 1 min.

J Invasive Cardiol. 1998 Nov;10(9):534-538.

Intravascular Red Light Therapy after Coronary Stenting N Angiographic and Clinical Follow-up Study in Humans.

Kaul U, Singh B, Sudan D, Ghose T, Kipshidze N.
Director, Interventional Cardiology, Batra Hospital and Medical Research Centre 1, Tughlakabad Institutional Area, Mehrauli Badarpur Road, New Delhi-110 062, India.

In animal models of coronary restenosis, intravascular red light therapy (IRLT) using a diode laser source has been shown to reduce neointimal hyperplasia following balloon-induced injury and coronary stenting. We studied the safety and efficacy of catheter-based IRLT for preventing restenosis after coronary stenting in 22 patients with angina pectoris. IRLT was performed using a diode laser (650 nm) at an energy level of 10 megawatts delivered through a rapid exchange balloon system containing the fiberoptics. The procedure was successful in all patients, with no procedural or in-hospital complications. Two patients with recurrence of symptoms had angiography at 3 and 4.1 months respectively. Angiographic follow-up was also done after 6 months in the 20 remaining asymptomatic patients. The mean minimal lumen diameter (MLD) for the whole group at 6 months follow-up was 2.57 +/- 0.62 mm. The calculated late lumen loss was 0.49 +/- 1.12 mm with a late loss index of 0.21 +/- 0.54. Four patients (2 symptomatic and 2 asymptomatic) in the series developed angiographic restenosis. Clinical events at follow-up of 10.9 +/- 3.5 months were repeat angioplasty in 2 patients for symptomatic restenosis with a 91% event free survival. These preliminary results demonstrate that IRLT after coronary artery stenting is safe and feasible; it is associated with low rates of angiographic indices of restenosis

J